Eaton LED nightlight with duplex receptacle, Tamper-resistant, 14 to 12 AWG, 15 A, flush mount, 120/277 V, back and side wiring, white, brass, 5-15R, two-pole, three-wire, grounding, thermoplastic , K.B.
Eaton LED nightlight with duplex receptacle, tamper-resistant, 14 to 12 AWG, 15 A, flush mount, 120/277 V, back and side wiring, Light almond, brass, 5-15R, two-pole, three-wire, grounding, Thermoplastic, KB.
Commercial Specification Grade Straight Blade Receptacles, 20 A to 125 V, NEMA 5-20R. Engineered for safe, reliable performance, these UL 498 and Federal Specification WC-596 listed devices provide maximum durability in a wide variety of applications while providing installation efficiency to help finish the job on time.
Commercial Specification Grade Straight Blade Receptacles, 20 A to 125 V, NEMA 5-20R. Engineered for safe, reliable performance, these UL 498 and Federal Specification WC-596 listed devices provide maximum durability in a wide variety of applications while providing installation efficiency to help finish the job on time.
Commercial specification-grade straight blade receptacles - 15 A, 125 V, NEMA 5-15R. Engineered for safe, reliable performance, these UL 498 and Federal Specification WC-596 listed devices provide maximum durability in a wide variety of applications while providing installation efficiency to help finish the job on time.
Standard duplex receptacles feature longer, wider straps providing 40% more contact area to the wallboard. Virtually eliminates floating installations. Patented built-in wire stripper for #14 and #12 wire to speed installation. Patented built-in wire looper for pre-looping. Tri-combo screws accept slotted, Phillips and Robertson-head tools for installation flexibility. Terminal screws backed out - ready for wiring. Side wire terminals accept up to #10 solid or stranded wire. Push-in terminals accept #14 solid wire.
Commercial specification-grade straight blade receptacles - 15 A-125 V, NEMA 5-15R. Engineered for safe, reliable performance, these UL 498 and Federal Specification WC-596 listed devices provide maximum durability in a wide variety of applications while providing installation efficiency to help finish the job on time.
Receptacles provide compliance with 2011 NEC Article 406.12 that states that all receptacles installed in dwelling units must be tamper-resistant. Durable impact-resistant thermoplastic face and back body is virtually unbreakable. "TR" designation provides visual identification. Terminal screws are backed out and ready to wire. Extra-long and extra-wide mounting straps with patented built-in wire stripper for #14 and #12 wire to speed installation. Side-wire terminals accept up to #10 solid or stranded wire and push-in terminals accept #14 solid wire.
Receptacles provide compliance with 2011 NEC Article 406.12 that states that all receptacles installed in dwelling units must be tamper-resistant. Durable impact-resistant thermoplastic face and back body is virtually unbreakable. "TR" designation provides visual identification. Terminal screws are backed out and ready to wire. Extra-long and extra-wide mounting straps with patented built-in wire stripper for #14 and #12 wire to speed installation. Side-wire terminals accept up to #10 solid or stranded wire and push-in terminals accept #14 solid wire.
Decorator receptacles feature longer, wider straps providing 40% more contact area to wall board. Virtually eliminates floating installations. Patented built-in wire stripper for #14 and #12 wire to speed installation. Patented built-in wire looper for pre-looping. Tri-combo screws accept slotted, Phillips and Robertson-head tools for installation flexibility. Terminal screws backed out - ready for wiring. Side wire terminals accept up to #10 solid or stranded wire. Push-in terminals accept #14 solid wire.
Provides compliance with 2011 NEC Article 406.12 that states that all receptacles installed in dwelling units must be tamper-resistant. Durable impact-resistant thermoplastic face and back body is virtually unbreakable. "TR" designation provides visual identification. Terminal screws are backed out and ready to wire. Extra-long and extra-wide mounting straps with patented built-in wire stripper for #14 and #12 wire to speed installation. Side-wire terminals accept up to #10 solid or stranded wire and push-in terminals accept #14 solid wire.
Provides compliance with 2011 NEC Article 406.12 that states that all receptacles installed in dwelling units must be tamper-resistant. Durable impact-resistant thermoplastic face and back body is virtually unbreakable. "TR" designation provides visual identification. Terminal screws are backed out and ready to wire. Extra-long and extra-wide mounting straps with patented built-in wire stripper for #14 and #12 wire to speed installation. Side-wire terminals accept up to #10 solid or stranded wire and push-in terminals accept #14 solid wire.
Decorator receptacles feature longer, wider straps providing 40% more contact area to wall board. Virtually eliminates floating installations. Patented built-in wire stripper for #14 and #12 wire to speed installation. Patented built-in wire looper for pre-looping. Tri-combo screws accept slotted, Phillips and Robertson-head tools for installation flexibility. Terminal screws backed out - ready for wiring. Side wire terminals accept up to #10 solid or stranded wire. Push-in terminals accept #14 solid wire.
Provides compliance with 2011 NEC Article 406.12 that states that all receptacles installed in dwelling units must be tamper-resistant. Durable impact-resistant thermoplastic face and back body is virtually unbreakable. "TR" designation provides visual identification. Terminal screws are backed out and ready to wire. Extra-long and extra-wide mounting straps with patented built-in wire stripper for #14 and #12 wire to speed installation. Side-wire terminals accept up to #10 solid or stranded wire and push-in terminals accept #14 solid wire.
Weather-resistant receptacle. Provides compliance with 2011 NEC Article 406.9 that states that all receptacles installed in wet and damp locations must be weather-resistant. "WR" designations provide visual identification. Weather-resistant receptacles offer protection from rain, snow, ice, moisture and humidity when properly installed in an approved weather protective or while-in-use cover. Weather-resistant receptacles are for use in any residential or commercial outdoor location. Designed with enhanced nylon and corrosion resistant metal components weather-resistant receptacles are extra durable. Combine WR receptacles with any of our WeatherBox while-in-use protective covers for tough protection against the elements.
Commercial specification-grade straight blade receptacles - tamper-and weather-resistant 15 A-125 V, NEMA 5-15R. Ensure safety and weather resistance in wet and damp outdoor locations with the ultimate in safety outlet protection. Provides compliance with 2011 NEC Article 406.9 that states that all receptacles installed in wet and damp locations must be weather-resistant. "TR" and "WR" designations provide visual identification.
Hospital specification-grade straight blade receptacles - premium back wire & side wire. Arrow Hart's feature rich line of hospital-grade receptacles have been designed to meet and exceed the demanding requirements of UL 498 and Federal Specification WC-596 to provide a consistent means of connectivity where downtime can be critical.
Commercial specification-grade straight blade receptacles - tamper-and weather-resistant 15 A - 125 V, NEMA 5-15R. Ensure safety and weather resistance in wet and damp outdoor locations with the ultimate in safety outlet protection. Provides compliance with 2011 NEC Article 406.9 that states that all receptacles installed in wet and damp locations must be weather-resistant. "TR" and "WR" designations provide visual identification.
Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for number 14 and number 12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to number 10 solid or stranded wire. Push in terminals accept number 14 solid wire. Screw-catch feature speeds wall plate installation. 15 amp, 125 volt. NEMA 5-15R. UL, cULus Listed.
Receptacles provide compliance with 2011 NEC Article 406.12 that states that all receptacles installed in dwelling units must be tamper-resistant. Durable impact-resistant thermoplastic face and back body is virtually unbreakable. "TR" designation provides visual identification. Terminal screws are backed out and ready to wire. Extra-long and extra-wide mounting straps with patented built-in wire stripper for #14 and #12 wire to speed installation. Side-wire terminals accept up to #10 solid or stranded wire and push-in terminals accept #14 solid wire.
Provides compliance with 2011 NEC Article 406.9 that states that all receptacles installed in wet and damp locations must be weather-resistant. "WR" designations provide visual identification. Weather-resistant receptacles offer protection from rain, snow, ice, moisture and humidity when properly installed in an approved weather protective or while-in-use cover. Weather-resistant receptacles are for use in any residential or commercial outdoor location. Designed with enhanced nylon and corrosion-resistant metal components weather-resistant receptacles are extra durable. Combine WR receptacles with any of our WeatherBox while-in-use protective covers for tough protection against the elements.
Commercial specification-grade straight blade receptacles. Tamper-resistant 20 A-125 V, NEMA 5-20R. Provides compliance with 2011 NEC Article 406.12 that states that all receptacles installed in dwelling units must be tamper resistant. "TR" designation provides visual identification.
Commercial specification-grade straight blade receptacles - 15 A-125 V, NEMA 5-15R. Engineered for safe, reliable performance, these UL 498 and Federal Specification WC-596 listed devices provide maximum durability in a wide variety of applications while providing installation efficiency to help finish the job on time.
Commercial specification-grade straight blade receptacles - tamper-resistant 15 A - 125 V, NEMA 5-15R. Provides compliance with 2011 NEC Article 406.12 that states that all receptacles installed in dwelling units must be tamper resistant. "TR" designations provide visual identification.
Commercial specification-grade straight blade receptacles - 20 A-125 V, NEMA 5-20R. Engineered for safe, reliable performance, these UL 498 and Federal Specification WC-596 listed devices provide maximum durability in a wide variety of applications while providing installation efficiency to help finish the job on time.
Longer, wider strap provides 40 percent more contact area to wall board. Virtually eliminates floating installations. Built-in wire stripper for number 14 and number 12 wire and wire looper for pre-looping. Combination slot/Phillips head mounting and terminal screws for installation with power screwdrivers. Terminal screws backed out - ready for wiring. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire. Temperature range of -40 to 65 degrees C. Meets all UL 498 requirements, (file no. E15058), Fed. Specs. WC-596G, NOM Certified, CSA Certified, C22.2 no.42. Standard Grade: (file no.6914) (6233-01). Meets flammability requirements per UL94, V2 rated. 15 amp, 125 volt.
Commercial specification-grade straight blade receptacles - 15 A-125 V, NEMA 5-15R. Engineered for safe, reliable performance, these UL 498 and Federal Specification WC-596 listed devices provide maximum durability in a wide variety of applications while providing installation efficiency to help finish the job on time.
Arrow Hart's feature rich line of hospital-grade receptacles have been designed to meet and exceed the demanding requirements of UL 498 and Federal Specification WC-596 to provide a consistent means of connectivity where downtime can be critical.
Commercial specification-grade straight blade receptacles - 20 A-125 V, NEMA 5-20R. Engineered for safe, reliable performance, these UL 498 and Federal Specification WC-596 listed devices provide maximum durability in a wide variety of applications while providing installation efficiency to help finish the job on time.
Tamper-resistant duplex receptacles provide compliance with 2011 NEC Article 406.12 that states that all receptacles installed in dwelling units must be tamper-resistant. Durable impact-resistant thermoplastic face and back body is virtually unbreakable. TR designation provides visual identification. Terminal screws are backed out and ready to wire. Extra-long and extra-wide mounting straps with patented built-in wire stripper for #14 and #12 wire to speed installation. Side-wire terminals accept up to #10 solid or stranded wire and push-in terminals accept #14 solid wire.
Tamper-resistant duplex receptacles provide compliance with 2011 NEC Article 406.12 that states that all receptacles installed in dwelling units must be tamper-resistant. Durable impact-resistant thermoplastic face and back body is virtually unbreakable. TR designation provides visual identification. Terminal screws are backed out and ready to wire. Extra-long and extra-wide mounting straps with patented built-in wire stripper for #14 and #12 wire to speed installation. Side-wire terminals accept up to #10 solid or stranded wire and push-in terminals accept #14 solid wire.
Decorator Receptacles with autoground feature longer, wider straps providing 40% more contact area to wall board. Virtually eliminates floating installations. Patented built-in wire stripper for #14 and #12 wire to speed installation. Patented built-in wire looper for pre-looping. Tri-combo screws accept slotted, Phillips and Robertson-head tools for installation flexibility. Terminal screws backed out - ready for wiring. Side wire terminals accept up to #10 solid or stranded wire. Push-in terminals accept #14 solid wire.
Commercial specification-grade straight blade receptacles - tamper-and weather-resistant 15 A-125 V, NEMA 5-15R. Ensure safety and weather resistance in wet and damp outdoor locations with the ultimate in safety outlet protection. Provides compliance with 2011 NEC Article 406.9 that states that all receptacles installed in wet and damp locations must be weather-resistant. "TR" and "WR" designations provide visual identification.
Longer, wider strap provides 40 percent more contact area to wall board. Virtually eliminates floating installations. Built-in wire stripper for number 14 and number 12 wire and wire looper for pre-looping. Combination slot/Phillips head mounting and terminal screws for installation with power screwdrivers. Terminal screws backed out - ready for wiring. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire. Temperature range of -40 to 65 degrees C. Meets all UL 498 requirements, (file no. E15058), Fed. Specs. WC-596G, NOM Certified, CSA Certified, C22.2 no.42. Standard Grade: (file no.6914) (6233-01). Meets flammability requirements per UL94, V2 rated. 15 amp, 125 volt.
Eaton Duplex Receptacle, 125 VAC, 15 A, Number of Poles: 2, Number of Wires: 3, Wiring Type: Push, Side, Wire Size: 14 to 10 AWG, NEMA Configuration: 5-15R, Operating Temperature: -4 to 140 deg F, Flush Mounting, Thermoplastic, White, Dimensions: 3.81 in H x 0.69 in W x 1.3 in D
Standard duplex receptacles feature longer, wider straps providing 40% more contact area to the wallboard. Virtually eliminates floating installations. Patented built-in wire stripper for #14 and #12 wire to speed installation. Patented built-in wire looper for pre-looping. Tri-combo screws accept slotted, Phillips and Robertson-head tools for installation flexibility. Terminal screws backed out - ready for wiring. Side wire terminals accept up to #10 solid or stranded wire. Push-in terminals accept #14 solid wire.
Provides compliance with 2011 NEC Article 406.12 that states that all receptacles installed in dwelling units must be tamper-resistant. Durable impact-resistant thermoplastic face and back body is virtually unbreakable. "TR" designation provides visual identification. Terminal screws are backed out and ready to wire. Extra-long and extra-wide mounting straps with patented built-in wire stripper for #14 and #12 wire to speed installation. Side-wire terminals accept up to #10 solid or stranded wire and push-in terminals accept #14 solid wire.
Commercial specification-grade straight blade receptacle on 4 in galvanized steel cover. Back and side wire. 15 A, 125 V. 5-15R NEMA. Temperature rating of -20 to 60 deg C. UL listed, meets all CSA requirements, NOM Certified.
Decorator receptacles feature longer, wider straps providing 40% more contact area to wall board. Virtually eliminates floating installations. Patented built-in wire stripper for #14 and #12 wire to speed installation. Patented built-in wire looper for pre-looping. Tri-combo screws accept slotted, Phillips and Robertson-head tools for installation flexibility. Terminal screws backed out - ready for wiring. Side wire terminals accept up to #10 solid or stranded wire. Push-in terminals accept #14 solid wire.
Meets all UL 498 requirements. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. 1/2 in thick steel wraparound mounting strap galvanized for corrosion resistance. Easy access split circuit break-off tab (except dual voltage). Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out; ready for wiring. Combination slot/Phillips head mounting and terminal screws.
Built-in wire stripper for #14 wire. Built-in wire looper for pre-looping conductors. Screw-catch feature eliminates need to hand-thread screw and possible cross-threading. Double wipe ground contacts. Split circuit break-off tab. Side wire terminals accept up to #10 solid or stranded wire. Push-in terminals accept #14 solid wire only. 15 A/125 V. UL listed, NOM certified, meets CSA requirements.
Commercial specification-grade straight blade receptacles - 15 A, 125 V, NEMA 5-15R. Engineered for safe, reliable performance, these UL 498 and Federal Specification WC-596 listed devices provide maximum durability in a wide variety of applications while providing installation efficiency to help finish the job on time.
Commercial-grade straight blade receptacles 15 A, 125 V, NEMA 5-15R. Engineered for safe, reliable performance, these UL 498 and Federal Specification WC-596 listed devices provide maximum durability in a wide variety of applications while providing installation efficiency to help finish the job on time.
Eaton Duplex Receptacle, 125 V, 15 A, Number of Poles: 2, Number of Wires: 3, Wiring Type: Back, Side, Wire Size: 14 to 10 AWG, NEMA Configuration: 5-15R, Flush Mounting, PVC, Ivory, Dimensions: 1.3 in L x 0.88 in W x 4.2 in H
Meets all UL 498 and 1567 requirements. Longer, wider strap provides 40 percent more contact area. Side wire terminals accept up to #10 solid or standard copper or aluminum wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws ease installation with power screwdrivers. 15 amp, 125 volt. Bulk pack.
Meets all UL 498 requirements. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. 1/2 in thick steel wraparound mounting strap galvanized for corrosion resistance. Easy access split circuit break-off tab (except dual voltage). Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out; ready for wiring. Combination slot/Phillips head mounting and terminal screws.
Standard duplex receptacles feature longer, wider straps providing 40% more contact area to the wallboard. Virtually eliminates floating installations. Patented built-in wire stripper for #14 and #12 wire to speed installation. Patented built-in wire looper for pre-looping. Tri-combo screws accept slotted, Phillips and Robertson-head tools for installation flexibility. Terminal screws backed out - ready for wiring. Side wire terminals accept up to #10 solid or stranded wire. Push-in terminals accept #14 solid wire.
Provides compliance with 2011 NEC Article 406.12 that states that all receptacles installed in dwelling units must be tamper-resistant. Durable impact-resistant thermoplastic face and back body is virtually unbreakable. "TR" designation provides visual identification. Terminal screws are backed out and ready to wire. Extra-long and extra-wide mounting straps with patented built-in wire stripper for #14 and #12 wire to speed installation. Side-wire terminals accept up to #10 solid or stranded wire and push-in terminals accept #14 solid wire.
Arrow Hart's feature rich line of Hospital Grade receptacles have been designed to meet and exceed the demanding requirements of UL 498 and Federal Specification WC-596 to provide a consistent means of connectivity where downtime can be critical.
Built-in wire stripper for #14 wire. Built-in wire looper for pre-looping conductors. Screw-catch feature eliminates need to hand-thread screw and possible cross-threading. Double wipe ground contacts. Split circuit break-off tab. Side wire terminals accept up to #10 solid or stranded wire. Push-in terminals accept #14 solid wire only. 15 A/125 V. UL listed, NOM certified, meets CSA requirements.
Meets all UL 498 and 1567 requirements. Longer, wider strap provides 40 percent more contact area. Side wire terminals accept up to #10 solid or standard copper or aluminum wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws ease installation with power screwdrivers. 15 amp, 125 volt. Bulk pack.
Commercial specification-grade straight blade receptacles - tamper-resistant 15 A - 125 V, NEMA 5-15R. Provides compliance with 2011 NEC Article 406.12 that states that all receptacles installed in dwelling units must be tamper resistant. "TR" designations provide visual identification.
Industrial Specification Grade Straight Blade Receptacles - 15 A-125 V, NEMA 5-15R. Designed from the inside out, these receptacles meet and exceed the UL 498 and Federal Specification WC-596 standards to withstand the most abusive environments and excel in applications that demand the highest levels of performance.
Meets all UL 498 requirements. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. 1/2 in thick steel wraparound mounting strap galvanized for corrosion resistance. Easy access split circuit break-off tab (except dual voltage). Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out; ready for wiring. Combination slot/Phillips head mounting and terminal screws.
Meets all UL 498 requirements. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. 1/2 in thick steel wraparound mounting strap galvanized for corrosion resistance. Easy access split circuit break-off tab (except dual voltage). Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out; ready for wiring. Combination slot/Phillips head mounting and terminal screws.
Commercial specification-grade straight blade receptacles 15 A - 125 V, NEMA 5-15R. Ensure safety and weather resistance in wet and damp outdoor locations with the ultimate in safety outlet protection. Tamper-and weather-resistant receptacles. Provides compliance with 2011 NEC Article 406.9 that states that all receptacles installed in wet and damp locations must be weather resistant. "TR" and "WR" designations provide visual identification.
Meets all UL 498 requirements. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. 1/2 in thick steel wraparound mounting strap galvanized for corrosion resistance. Easy access split circuit break-off tab (except dual voltage). Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out; ready for wiring. Combination slot/Phillips head mounting and terminal screws.
Meets all UL 498 requirements. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. 1/2 in thick steel wraparound mounting strap galvanized for corrosion resistance. Easy access split circuit break-off tab (except dual voltage). Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out; ready for wiring. Combination slot/Phillips head mounting and terminal screws.
Standard duplex receptacles feature longer, wider straps providing 40% more contact area to the wallboard. Virtually eliminates floating installations. Patented built-in wire stripper for #14 and #12 wire to speed installation. Patented built-in wire looper for pre-looping. Tri-combo screws accept slotted, Phillips and Robertson-head tools for installation flexibility. Terminal screws backed out - ready for wiring. Side wire terminals accept up to #10 solid or stranded wire. Push-in terminals accept #14 solid wire.
Standard duplex receptacles feature longer, wider straps providing 40% more contact area to the wallboard. Virtually eliminates floating installations. Patented built-in wire stripper for #14 and #12 wire to speed installation. Patented built-in wire looper for pre-looping. Tri-combo screws accept slotted, Phillips and Robertson-head tools for installation flexibility. Terminal screws backed out - ready for wiring. Side wire terminals accept up to #10 solid or stranded wire. Push-in terminals accept #14 solid wire.
Provides compliance with 2011 NEC Article 406.12 that states that all receptacles installed in dwelling units must be tamper-resistant. Durable impact-resistant thermoplastic face and back body is virtually unbreakable. "TR" designation provides visual identification. Terminal screws are backed out and ready to wire. Extra-long and extra-wide mounting straps with patented built-in wire stripper for #14 and #12 wire to speed installation. Side-wire terminals accept up to #10 solid or stranded wire and push-in terminals accept #14 solid wire.
Receptacles provide compliance with 2011 NEC Article 406.12 that states that all receptacles installed in dwelling units must be tamper-resistant. Durable impact-resistant thermoplastic face and back body is virtually unbreakable. "TR" designation provides visual identification. Terminal screws are backed out and ready to wire. Extra-long and extra-wide mounting straps with patented built-in wire stripper for #14 and #12 wire to speed installation. Side-wire terminals accept up to #10 solid or stranded wire and push-in terminals accept #14 solid wire.
Standard duplex receptacles feature longer, wider straps providing 40% more contact area to the wallboard. Virtually eliminates floating installations. Patented built-in wire stripper for #14 and #12 wire to speed installation. Patented built-in wire looper for pre-looping. Tri-combo screws accept slotted, Phillips and Robertson-head tools for installation flexibility. Terminal screws backed out - ready for wiring. Side wire terminals accept up to #10 solid or stranded wire. Push-in terminals accept #14 solid wire.
Hospital specification-grade straight blade receptacles - isolated ground premium back wire & side wire. Arrow Hart's feature rich line of hospital-grade receptacles have been designed to meet and exceed the demanding requirements of UL 498 and Federal Specification WC-596 to provide a consistent means of connectivity where downtime can be critical.
Commercial specification-grade straight blade receptacles - 15 A, 125 V, NEMA 5-15R. Engineered for safe, reliable performance, these UL 498 and Federal Specification WC-596 listed devices provide maximum durability in a wide variety of applications while providing installation efficiency to help finish the job on time.
Commercial specification-grade straight blade receptacles - 15 A-125 V, NEMA 5-15R. Engineered for safe, reliable performance, these UL 498 and Federal Specification WC-596 listed devices provide maximum durability in a wide variety of applications while providing installation efficiency to help finish the job on time.
Commercial specification-grade straight blade receptacles. Tamper-resistant 20 A-125 V, NEMA 5-20R. Provides compliance with 2011 NEC Article 406.12 that states that all receptacles installed in dwelling units must be tamper resistant. "TR" designation provides visual identification.
Commercial specification-grade straight blade receptacles - 15 A-125 V, NEMA 5-15R. Engineered for safe, reliable performance, these UL 498 and Federal Specification WC-596 listed devices provide maximum durability in a wide variety of applications while providing installation efficiency to help finish the job on time.