Charlotte Pipe, Plain End, Nominal Size: 1-1/2 in, 1.9 in Dia Outside, Wall Thickness: 0.145 in, 20 ft L, Operating Temperature: <140 deg F, Schedule Rating: SCH 40, PVC, White
Charlotte Pipe, Nominal Size: 4 in, 4-1/2 in Dia Outside, Wall Thickness: 0.237 in, 20 ft L, Operating Temperature: 32 to 140 deg F, Schedule Rating: SCH 40, PVC, White
Charlotte Pipe, Nominal Size: 4 in, 4-1/2 in Dia Outside, Wall Thickness: 0.237 in, 10 ft L, Operating Temperature: 140 deg F, Schedule Rating: SCH 40, PVC, White
Charlotte Pipe, Nominal Size: 2 in, 2-3/8 in Dia Outside, Wall Thickness: 0.154 in, 10 ft L, 280 psi, Operating Temperature: 140 deg F, Schedule Rating: SCH 40, PVC, White
JM Eagle solvent weld Schedule Series pipes are suitable for use in both pressure and drain, waste and vent applications. JM Eagle's wide line of solvent weld includes PVC schedule 40 and 80 for both pressure and non-pressure applications. The pipes are available in 10 or 20 ft lengths, in 1/2 to 16 in Dia in schedule 40, bell end and 1/2 to 12 in Dia in schedule 80, plain end. JM Eagle's ASTM 1785 product also comes in a specially formulated PVC material to increase resistance to ultraviolet rays. Called SolarBlok, it comes in IPS, 20 ft lengths, in brown. Solvent weld joints are designed to provide a rigid joint connection and the schedule-rated products are specifically engineered for use in partial support systems above ground. A 20 ft length of solvent weld schedule 40 PVC water pipe weighs approximately 72 lb.
JM Eagle's wide line of solvent weld pipe includes PVC schedule 30 and 40 in solid wall and schedule 40 in cellular-core. Solvent weld joints are designed to provide a rigid (or restrained) joint connection in a solid core, schedule 30 pipe is available in 3-1/4 in Dia and schedule 40 is available in 1/2 through 16 in Dia. Schedule 40 cellular-core is available in 1-1/2 through 12 in Dia. DWV pipe comes in 10 and 20 ft lengths in plain and bell end.
JM Eagle's wide line of solvent weld pipe includes PVC Schedule 30 and 40 in solid wall and Schedule 40 in cellular core. Solvent weld joints are designed to provide a rigid (or restrained) joint connection in a solid core, Schedule 30 pipe is available in 3-1/4 in Dia, and Schedule 40 is available in 1/2 in through 16 in Dia. Schedule 40 cellular core is available in 1-1/2 in through 12 in Dia. DWV pipe comes in 10 ft and 20 ft lengths in plain and bell end.
Charlotte Pipe, Cellular Core, Plain End, Nominal Size: 3 in, 3-1/2 in Dia Outside, Wall Thickness: 0.216 in, 20 ft L, Operating Temperature: 32 to 140 deg F, Schedule Rating: SCH 40, PVC, White
Solvent weld, use for drain-waste-vent applications, or with pressure fittings for pressure pipe applications. Lightweight, high-impact resistant, and corrosion-proof, resistant to all waste system liquids and gases. PSI ratings at 73 degrees Fahrenheit range from 180 (6" pipe) to 330 (1-1/2" pipe) depending on ID size. Dual rated for pressure (ASTM D1785) and drainage (ASTM D2665).
Charlotte Pipe, Nominal Size: 2 in, 2-3/8 in Dia Outside, Wall Thickness: 0.154 in, 20 ft L, 280 psi, Operating Temperature: 32 to 140 deg F, Schedule Rating: SCH 40, PVC, White
Charlotte Pipe, Foam Core, Plain End, Nominal Size: 1-1/2 in, 1.9 in Dia Outside, Wall Thickness: 0.145 in, 20 ft L, Operating Temperature: <140 deg F, Schedule Rating: SCH 40, PVC, White
Charlotte Pipe, Cellular Core, Nominal Size: 3 in, 3-1/2 in Dia Outside, Wall Thickness: 0.216 in, 10 ft L, Operating Temperature: 32 to 140 deg F, Schedule Rating: SCH 40, PVC, White
Charlotte Pipe, Plain End, Nominal Size: 6 in, 6-5/8 in Dia Outside, Wall Thickness: 0.28 in, 10 ft L, 190 psi, Operating Temperature: 32 to 140 deg F, Schedule Rating: SCH 40, PVC, White
Charlotte Pipe, Nominal Size: 3 in, 3-1/2 in Dia Outside, Wall Thickness: 0.216 in, 20 ft L, 260 psi, Operating Temperature: 32 to 140 deg F, Schedule Rating: SCH 40, PVC, White
PVC SCH 40 is highly durable, with high tensile and impact strength. It is easy to install and has better sound deadening qualities than PVC SCH 40 DWV foam core. Installation requires the use of primer and solvent cement. For pressure applications, sharply angled pressure fittings must be used.
Charlotte Pipe, Foam Core, Plain End, Nominal Size: 2 in, 2-3/8 in Dia Outside, Wall Thickness: 0.154 in, 20 ft L, Operating Temperature: <140 deg F, Schedule Rating: SCH 40, PVC, White